اینورتر تک فاز فتوولتائیک بدون ترانسفورماتور با مهار رزونانس در H6 بهبود یافته
تعداد صفحات انگلیسی 14 صفحه
تعداد صفحات فارسی 27 صفحه تعداد کلمات:6050
Abstract— In low power applications of photovoltaic (PV) systems, the transformerless grid-connected inverters have been preferred to increase the efficiency and reduce the cost, size and power losses when they are compared to the ones with the transformer. A transformerless single-phase inverter topology with a single DC link capacitor for the grid-connected PV systems is proposed in this paper. The proposed inverter has been simulated by using a cooperation process of the MATLAB and SPICE package programs and it has been implemented for experimental verification. The proposed inverter reduces the high-frequency common mode leakage current caused by parasitic capacitances of PV panels, while it is controlled with the unipolar sinusoidal pulse width modulation (SPWM). Also, the results show that the common mode voltage remains constant. The efficiency of the proposed inverter has been compared to that of the most common topologies having the DC link decoupling during the zero voltage states. This paper is accompanied by a video file demonstrating the power loss distribution in the inverter.
چکیده
در کاربردهای توان پایین سیستم های فتوولتائیک (PV) ، اینورترهای متصل به شبکه بدون ترانسفورمر برای افزایش بهره وری و کاهش هزینه ، اندازه و تلفات توان به اینورترهای با ترانسفورماتور( بعد از مقایسه انجام شده بین این دو اینورتر) ترجیح داده شده اند. یک توپولوژی اینورتر تک فاز بدون ترانسفورماتور با یک خازن لینک DC برای سیستمهای PV متصل به شبکه در این مقاله ارائه شده است. اینورتر پیشنهادی با استفاده از یک فرایند همکاری برنامه های MATLAB و SPICE شبیه سازی شده و برای تأیید نتایج اجرا شده است. اینورتر پیشنهادی در حالی که با مدولاسیون عرض پالس سینوسی تک قطبی (SPWM) کنترل می شود، جریان نشت مد (حالت) مشترک با فرکانس بالا را که ناشی از خازن های پارازیتی (انگلی) پنل های PV است کاهش می دهد. همچنین نتایج نشان میدهد که ولتاژ حالت مشترک ثابت باقی میماند. راندمان اینورتر پیشنهادی با متداول ترین توپولوژیهای رایج که دارای جداسازی اتصال لینک DC در هنگام حالت های ولتاژ صفر هستند مقایسه شده است. این مقاله با یک فایل ویدیویی همراه است که توزیع تلفات توان را در اینورتر نشان می دهد.
دانلود رایگان مقاله انگلیسی

توضیحات محصول
اینورتر تک فاز فتوولتائیک بدون ترانسفورماتور با مهار رزونانس در H6 بهبود یافته
تعداد صفحات انگلیسی 14 صفحه
تعداد صفحات فارسی 27 صفحه تعداد کلمات:6050
Abstract— In low power applications of photovoltaic (PV) systems, the transformerless grid-connected inverters have been preferred to increase the efficiency and reduce the cost, size and power losses when they are compared to the ones with the transformer. A transformerless single-phase inverter topology with a single DC link capacitor for the grid-connected PV systems is proposed in this paper. The proposed inverter has been simulated by using a cooperation process of the MATLAB and SPICE package programs and it has been implemented for experimental verification. The proposed inverter reduces the high-frequency common mode leakage current caused by parasitic capacitances of PV panels, while it is controlled with the unipolar sinusoidal pulse width modulation (SPWM). Also, the results show that the common mode voltage remains constant. The efficiency of the proposed inverter has been compared to that of the most common topologies having the DC link decoupling during the zero voltage states. This paper is accompanied by a video file demonstrating the power loss distribution in the inverter.
چکیده
در کاربردهای توان پایین سیستم های فتوولتائیک (PV) ، اینورترهای متصل به شبکه بدون ترانسفورمر برای افزایش بهره وری و کاهش هزینه ، اندازه و تلفات توان به اینورترهای با ترانسفورماتور( بعد از مقایسه انجام شده بین این دو اینورتر) ترجیح داده شده اند. یک توپولوژی اینورتر تک فاز بدون ترانسفورماتور با یک خازن لینک DC برای سیستمهای PV متصل به شبکه در این مقاله ارائه شده است. اینورتر پیشنهادی با استفاده از یک فرایند همکاری برنامه های MATLAB و SPICE شبیه سازی شده و برای تأیید نتایج اجرا شده است. اینورتر پیشنهادی در حالی که با مدولاسیون عرض پالس سینوسی تک قطبی (SPWM) کنترل می شود، جریان نشت مد (حالت) مشترک با فرکانس بالا را که ناشی از خازن های پارازیتی (انگلی) پنل های PV است کاهش می دهد. همچنین نتایج نشان میدهد که ولتاژ حالت مشترک ثابت باقی میماند. راندمان اینورتر پیشنهادی با متداول ترین توپولوژیهای رایج که دارای جداسازی اتصال لینک DC در هنگام حالت های ولتاژ صفر هستند مقایسه شده است. این مقاله با یک فایل ویدیویی همراه است که توزیع تلفات توان را در اینورتر نشان می دهد.
دانلود رایگان مقاله انگلیسی